<?xml version="1.0" encoding="utf-8"?> <SRProject xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema"> <Standard>3</Standard> <Cases> <SRCase3> <CaseName>Original Case</CaseName> <Title>IEC 62305-2 [2010] Example E3 - Office building</Title> <ConsiderR1>true</ConsiderR1> <ConsiderR2>false</ConsiderR2> <ConsiderR3>false</ConsiderR3> <ConsiderR4>false</ConsiderR4> <CaseNote>As a second case study, an office building with an archive, offices and a computer centre is considered (Figure E.2). Loss of human life (L1) and economic loss (L4) are relevant for this type of structure. It is required to evaluate the need for protection. This implies the determination of only the risk R1 for loss of human life (L1) with the risk components RA, RB, RU and RV (according to Table 2) and to compare it with the tolerable risk RT = 10–5 (according to Table 4). Suitable protection measures will be selected to reduce the risk to or below the tolerable risk. Following the decision taken by the owner an economic evaluation is not requested; therefore the risk R4 for economic loss (L4) is not considered. </CaseNote> <FlashDensityInputMode>0</FlashDensityInputMode> <FlashDensity>4</FlashDensity> <Rho>500</Rho> <ServiceLineDensity>0</ServiceLineDensity> <CE>1</CE> <Structures> <SRStructure3> <Identification>Primary Structure</Identification> <Shape>0</Shape> <Dimension1>20</Dimension1> <Dimension2>40</Dimension2> <Dimension3>25</Dimension3> <Dimension4>0</Dimension4> <LocationRelativeToSurroundings>2</LocationRelativeToSurroundings> <Cd>1</Cd> </SRStructure3> </Structures> <PrimaryStructureIndex>0</PrimaryStructureIndex> <StructureShieldValue>0</StructureShieldValue> <KS1>1</KS1> <MeshWidth>0</MeshWidth> <Lines> <SRLine3> <Identification>L1 - Power line</Identification> <IncomingLineType>0</IncomingLineType> <IncomingLineShielding>0</IncomingLineShielding> <InternalWiringType>1</InternalWiringType> <ServiceEntranceSpd>0</ServiceEntranceSpd> <CoordinatedSpdSet>0</CoordinatedSpdSet> <ConnectedEquipmentWithstand>2</ConnectedEquipmentWithstand> <LocationRelativeToSurroundings>0</LocationRelativeToSurroundings> <ShieldingGroundingIsolation>0</ShieldingGroundingIsolation> <LineSections> <SRLineSection3> <Identification>LS1</Identification> <TypeOfServiceToTheStructure>0</TypeOfServiceToTheStructure> <HeightOfLine>0</HeightOfLine> <LengthOfLine>200</LengthOfLine> <PresenceOfTransformer>0</PresenceOfTransformer> <Ca>1</Ca> <Ct>1</Ct> </SRLineSection3> </LineSections> <ConnectedRemoteStructureIndex>-1</ConnectedRemoteStructureIndex> <CostOfCoordinatedProtection>0</CostOfCoordinatedProtection> <CostOfServiceProtection>0</CostOfServiceProtection> <ShieldingGroundingAndIsolation>0</ShieldingGroundingAndIsolation> <PSPDe>1</PSPDe> <UW>2.5</UW> <PSPDc>1</PSPDc> <Cdc>0</Cdc> <KS3>0.2</KS3> </SRLine3> <SRLine3> <Identification>L2 - Telecom line</Identification> <IncomingLineType>1</IncomingLineType> <IncomingLineShielding>0</IncomingLineShielding> <InternalWiringType>0</InternalWiringType> <ServiceEntranceSpd>0</ServiceEntranceSpd> <CoordinatedSpdSet>0</CoordinatedSpdSet> <ConnectedEquipmentWithstand>1</ConnectedEquipmentWithstand> <LocationRelativeToSurroundings>0</LocationRelativeToSurroundings> <ShieldingGroundingIsolation>0</ShieldingGroundingIsolation> <LineSections> <SRLineSection3> <Identification>LS1</Identification> <TypeOfServiceToTheStructure>1</TypeOfServiceToTheStructure> <HeightOfLine>0</HeightOfLine> <LengthOfLine>1000</LengthOfLine> <PresenceOfTransformer>0</PresenceOfTransformer> <Ca>0.5</Ca> <Ct>1</Ct> </SRLineSection3> </LineSections> <ConnectedRemoteStructureIndex>-1</ConnectedRemoteStructureIndex> <CostOfCoordinatedProtection>0</CostOfCoordinatedProtection> <CostOfServiceProtection>0</CostOfServiceProtection> <ShieldingGroundingAndIsolation>0</ShieldingGroundingAndIsolation> <PSPDe>1</PSPDe> <UW>1.5</UW> <PSPDc>1</PSPDc> <Cdc>0</Cdc> <KS3>1</KS3> </SRLine3> </Lines> <Zones> <SRZone3> <Identification>Z1 - Entrance area</Identification> <ZoneLocation>1</ZoneLocation> <TypeOfSoilOrFloor>2</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>0</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>0.001</ru> <rf>0</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>0</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>0</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>4</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>1</hZ1> <Lt1>0.01</Lt1> <Lf1>0</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z2 - Garden (outside)</Identification> <ZoneLocation>1</ZoneLocation> <TypeOfSoilOrFloor>0</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>0</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>0.01</ru> <rf>0</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>0</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>0</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>2</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>1</hZ1> <Lt1>0.01</Lt1> <Lf1>0</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>true</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z3 - Archive</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>4</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.1</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>20</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z4 - Offices</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>6</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.001</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>160</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z5 - Computer centre</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>6</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.001</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>14</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> </Zones> <LightningProtectionSystem>0</LightningProtectionSystem> <PB>1</PB> <CostOfLPS>0</CostOfLPS> <Financial> <InterestRate>0.001</InterestRate> <AmortizationRate>0.001</AmortizationRate> <MaintenanceRate>0.001</MaintenanceRate> <CostOfLoss>0</CostOfLoss> </Financial> <UnprotectedCaseIndex>-1</UnprotectedCaseIndex> </SRCase3> <SRCase3> <CaseName>Solution A</CaseName> <Title>IEC 62305-2 [2010] Example E3 - Office building</Title> <ConsiderR1>true</ConsiderR1> <ConsiderR2>false</ConsiderR2> <ConsiderR3>false</ConsiderR3> <ConsiderR4>false</ConsiderR4> <CaseNote>The risk R1 in the structure is mainly concentrated in zone Z3 due to physical damages caused by lightning striking the structure or the connected lines (components RB ≈ 49 % and RV ≈ 50 % together cover 99 % of the total risk) (see Table E.20). These dominant risk components can be reduced by: providing the whole building with an LPS conforming to EN 62305-3 reducing component RB via probability PB. Lightning equipotential bonding at the entrance – a mandatory requirement of the LPS - reduces also the components RU and RV via probability PEB, providing zone Z3 (archive) with protection measures against the consequences of fire (such as extinguishers, automatic fire detection system etc.). This will reduce the components RB and RV via the reduction factor rp, providing lightning equipotential bonding conforming to EN 62305-3 at the entrance of the building. This will reduce only the components RU and RV via probability PEB. Combining different elements of these protective measures the following solution could be adopted: protect the building with a Class III LPS conforming to EN 62305-3, to reduce component RB (PB = 0,1); this LPS includes the mandatory lightning equipotential bonding at the entrance with SPDs designed for LPL III (PEB = 0,05) and reduces components RU and RV.</CaseNote> <FlashDensityInputMode>0</FlashDensityInputMode> <FlashDensity>4</FlashDensity> <Rho>500</Rho> <ServiceLineDensity>0</ServiceLineDensity> <CE>1</CE> <Structures> <SRStructure3> <Identification>Primary Structure</Identification> <Shape>0</Shape> <Dimension1>20</Dimension1> <Dimension2>40</Dimension2> <Dimension3>25</Dimension3> <Dimension4>0</Dimension4> <LocationRelativeToSurroundings>2</LocationRelativeToSurroundings> <Cd>1</Cd> </SRStructure3> </Structures> <PrimaryStructureIndex>0</PrimaryStructureIndex> <StructureShieldValue>0</StructureShieldValue> <KS1>1</KS1> <MeshWidth>0</MeshWidth> <Lines> <SRLine3> <Identification>L1 - Power line</Identification> <IncomingLineType>0</IncomingLineType> <IncomingLineShielding>0</IncomingLineShielding> <InternalWiringType>1</InternalWiringType> <ServiceEntranceSpd>2</ServiceEntranceSpd> <CoordinatedSpdSet>0</CoordinatedSpdSet> <ConnectedEquipmentWithstand>2</ConnectedEquipmentWithstand> <LocationRelativeToSurroundings>0</LocationRelativeToSurroundings> <ShieldingGroundingIsolation>0</ShieldingGroundingIsolation> <LineSections> <SRLineSection3> <Identification>LS1</Identification> <TypeOfServiceToTheStructure>0</TypeOfServiceToTheStructure> <HeightOfLine>0</HeightOfLine> <LengthOfLine>200</LengthOfLine> <PresenceOfTransformer>0</PresenceOfTransformer> <Ca>1</Ca> <Ct>1</Ct> </SRLineSection3> </LineSections> <ConnectedRemoteStructureIndex>-1</ConnectedRemoteStructureIndex> <CostOfCoordinatedProtection>0</CostOfCoordinatedProtection> <CostOfServiceProtection>0</CostOfServiceProtection> <ShieldingGroundingAndIsolation>0</ShieldingGroundingAndIsolation> <PSPDe>0.05</PSPDe> <UW>2.5</UW> <PSPDc>1</PSPDc> <Cdc>0</Cdc> <KS3>0.2</KS3> </SRLine3> <SRLine3> <Identification>L2 - Telecom line</Identification> <IncomingLineType>1</IncomingLineType> <IncomingLineShielding>0</IncomingLineShielding> <InternalWiringType>0</InternalWiringType> <ServiceEntranceSpd>2</ServiceEntranceSpd> <CoordinatedSpdSet>0</CoordinatedSpdSet> <ConnectedEquipmentWithstand>1</ConnectedEquipmentWithstand> <LocationRelativeToSurroundings>0</LocationRelativeToSurroundings> <ShieldingGroundingIsolation>0</ShieldingGroundingIsolation> <LineSections> <SRLineSection3> <Identification>LS1</Identification> <TypeOfServiceToTheStructure>1</TypeOfServiceToTheStructure> <HeightOfLine>0</HeightOfLine> <LengthOfLine>1000</LengthOfLine> <PresenceOfTransformer>0</PresenceOfTransformer> <Ca>0.5</Ca> <Ct>1</Ct> </SRLineSection3> </LineSections> <ConnectedRemoteStructureIndex>-1</ConnectedRemoteStructureIndex> <CostOfCoordinatedProtection>0</CostOfCoordinatedProtection> <CostOfServiceProtection>0</CostOfServiceProtection> <ShieldingGroundingAndIsolation>0</ShieldingGroundingAndIsolation> <PSPDe>0.05</PSPDe> <UW>1.5</UW> <PSPDc>1</PSPDc> <Cdc>0</Cdc> <KS3>1</KS3> </SRLine3> </Lines> <Zones> <SRZone3> <Identification>Z1 - Entrance area</Identification> <ZoneLocation>1</ZoneLocation> <TypeOfSoilOrFloor>2</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>0</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>0.001</ru> <rf>0</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>0</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>0</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>4</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>1</hZ1> <Lt1>0.01</Lt1> <Lf1>0</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z2 - Garden (outside)</Identification> <ZoneLocation>1</ZoneLocation> <TypeOfSoilOrFloor>0</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>0</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>0.01</ru> <rf>0</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>0</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>0</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>2</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>1</hZ1> <Lt1>0.01</Lt1> <Lf1>0</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>true</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z3 - Archive</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>4</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.1</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>20</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z4 - Offices</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>6</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.001</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>160</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z5 - Computer centre</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>6</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.001</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>14</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> </Zones> <LightningProtectionSystem>2</LightningProtectionSystem> <PB>0.1</PB> <CostOfLPS>0</CostOfLPS> <Financial> <InterestRate>0.001</InterestRate> <AmortizationRate>0.001</AmortizationRate> <MaintenanceRate>0.001</MaintenanceRate> <CostOfLoss>0</CostOfLoss> </Financial> <UnprotectedCaseIndex>-1</UnprotectedCaseIndex> </SRCase3> <SRCase3> <CaseName>Solution B</CaseName> <Title>IEC 62305-2 [2010] Example E3 - Office building</Title> <ConsiderR1>true</ConsiderR1> <ConsiderR2>false</ConsiderR2> <ConsiderR3>false</ConsiderR3> <ConsiderR4>false</ConsiderR4> <CaseNote>The risk R1 in the structure is mainly concentrated in zone Z3 due to physical damages caused by lightning striking the structure or the connected lines (components RB ≈ 49 % and RV ≈ 50 % together cover 99 % of the total risk) (see Table E.20). These dominant risk components can be reduced by: providing the whole building with an LPS conforming to EN 62305-3 reducing component RB via probability PB. Lightning equipotential bonding at the entrance – a mandatory requirement of the LPS - reduces also the components RU and RV via probability PEB, providing zone Z3 (archive) with protection measures against the consequences of fire (such as extinguishers, automatic fire detection system etc.). This will reduce the components RB and RV via the reduction factor rp, providing lightning equipotential bonding conforming to EN 62305-3 at the entrance of the building. This will reduce only the components RU and RV via probability PEB. Combining different elements of these protective measures the following solution could be adopted: protect the building with a Class IV LPS conforming to EN 62305-3, to reduce component RB (PB = 0,2); this LPS includes the mandatory lightning equipotential bonding at the entrance with SPDs designed for LPL IV (PEB = 0,05) and reduces components RU and RV; use fire extinguishing (or detection) systems to reduce components RB and RV. Install a manual system in the zone Z3 (archive) (rp = 0,5).</CaseNote> <FlashDensityInputMode>0</FlashDensityInputMode> <FlashDensity>4</FlashDensity> <Rho>500</Rho> <ServiceLineDensity>0</ServiceLineDensity> <CE>1</CE> <Structures> <SRStructure3> <Identification>Primary Structure</Identification> <Shape>0</Shape> <Dimension1>20</Dimension1> <Dimension2>40</Dimension2> <Dimension3>25</Dimension3> <Dimension4>0</Dimension4> <LocationRelativeToSurroundings>2</LocationRelativeToSurroundings> <Cd>1</Cd> </SRStructure3> </Structures> <PrimaryStructureIndex>0</PrimaryStructureIndex> <StructureShieldValue>0</StructureShieldValue> <KS1>1</KS1> <MeshWidth>0</MeshWidth> <Lines> <SRLine3> <Identification>L1 - Power line</Identification> <IncomingLineType>0</IncomingLineType> <IncomingLineShielding>0</IncomingLineShielding> <InternalWiringType>1</InternalWiringType> <ServiceEntranceSpd>1</ServiceEntranceSpd> <CoordinatedSpdSet>0</CoordinatedSpdSet> <ConnectedEquipmentWithstand>2</ConnectedEquipmentWithstand> <LocationRelativeToSurroundings>0</LocationRelativeToSurroundings> <ShieldingGroundingIsolation>0</ShieldingGroundingIsolation> <LineSections> <SRLineSection3> <Identification>LS1</Identification> <TypeOfServiceToTheStructure>0</TypeOfServiceToTheStructure> <HeightOfLine>0</HeightOfLine> <LengthOfLine>200</LengthOfLine> <PresenceOfTransformer>0</PresenceOfTransformer> <Ca>1</Ca> <Ct>1</Ct> </SRLineSection3> </LineSections> <ConnectedRemoteStructureIndex>-1</ConnectedRemoteStructureIndex> <CostOfCoordinatedProtection>0</CostOfCoordinatedProtection> <CostOfServiceProtection>0</CostOfServiceProtection> <ShieldingGroundingAndIsolation>0</ShieldingGroundingAndIsolation> <PSPDe>0.05</PSPDe> <UW>2.5</UW> <PSPDc>1</PSPDc> <Cdc>0</Cdc> <KS3>0.2</KS3> </SRLine3> <SRLine3> <Identification>L2 - Telecom line</Identification> <IncomingLineType>1</IncomingLineType> <IncomingLineShielding>0</IncomingLineShielding> <InternalWiringType>0</InternalWiringType> <ServiceEntranceSpd>1</ServiceEntranceSpd> <CoordinatedSpdSet>0</CoordinatedSpdSet> <ConnectedEquipmentWithstand>1</ConnectedEquipmentWithstand> <LocationRelativeToSurroundings>0</LocationRelativeToSurroundings> <ShieldingGroundingIsolation>0</ShieldingGroundingIsolation> <LineSections> <SRLineSection3> <Identification>LS1</Identification> <TypeOfServiceToTheStructure>1</TypeOfServiceToTheStructure> <HeightOfLine>0</HeightOfLine> <LengthOfLine>1000</LengthOfLine> <PresenceOfTransformer>0</PresenceOfTransformer> <Ca>0.5</Ca> <Ct>1</Ct> </SRLineSection3> </LineSections> <ConnectedRemoteStructureIndex>-1</ConnectedRemoteStructureIndex> <CostOfCoordinatedProtection>0</CostOfCoordinatedProtection> <CostOfServiceProtection>0</CostOfServiceProtection> <ShieldingGroundingAndIsolation>0</ShieldingGroundingAndIsolation> <PSPDe>0.05</PSPDe> <UW>1.5</UW> <PSPDc>1</PSPDc> <Cdc>0</Cdc> <KS3>1</KS3> </SRLine3> </Lines> <Zones> <SRZone3> <Identification>Z1 - Entrance area</Identification> <ZoneLocation>1</ZoneLocation> <TypeOfSoilOrFloor>2</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>0</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>0.001</ru> <rf>0</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>0</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>0</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>4</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>1</hZ1> <Lt1>0.01</Lt1> <Lf1>0</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z2 - Garden (outside)</Identification> <ZoneLocation>1</ZoneLocation> <TypeOfSoilOrFloor>0</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>0</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>0.01</ru> <rf>0</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>0</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>0</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>2</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>1</hZ1> <Lt1>0.01</Lt1> <Lf1>0</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>true</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z3 - Archive</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>4</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>1</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.1</rf> <rp>0.5</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>20</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z4 - Offices</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>6</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.001</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>160</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> <SRZone3> <Identification>Z5 - Computer centre</Identification> <ZoneLocation>0</ZoneLocation> <TypeOfSoilOrFloor>7</TypeOfSoilOrFloor> <RiskOfFireOrPhysicalDamage>6</RiskOfFireOrPhysicalDamage> <FireProtectionSystem>0</FireProtectionSystem> <ShieldAtZoneBoundary>0</ShieldAtZoneBoundary> <ru>1E-05</ru> <rf>0.001</rf> <rp>1</rp> <KS2>1</KS2> <MeshWidth>0</MeshWidth> <CostOfFireProtection>0</CostOfFireProtection> <CostOfShieldProtection>0</CostOfShieldProtection> <L1DueToSpecialHazard>1</L1DueToSpecialHazard> <L1DueToStepAndTouchVoltage>1</L1DueToStepAndTouchVoltage> <L1DueToFireOrPhysicalDamage>3</L1DueToFireOrPhysicalDamage> <L1DueToOvervoltage>0</L1DueToOvervoltage> <NumberOfPersonsInZone>14</NumberOfPersonsInZone> <HoursPresentPerYear>8760</HoursPresentPerYear> <DaysPresentPerWeek>7</DaysPresentPerWeek> <HoursPresentPerDay>24</HoursPresentPerDay> <WeeksPresentPerYear>52</WeeksPresentPerYear> <hZ1>2</hZ1> <Lt1>0.01</Lt1> <Lf1>0.02</Lf1> <Lo1>0</Lo1> <L2DueToFireOrPhysicalDamage>0</L2DueToFireOrPhysicalDamage> <L2DueToOvervoltage>0</L2DueToOvervoltage> <NumberOfUsersServedByZone>0</NumberOfUsersServedByZone> <L2TreatStructureAsASingleZone>false</L2TreatStructureAsASingleZone> <Lf2>0</Lf2> <Lo2>0</Lo2> <L3DueToFireOrPhysicalDamage>0</L3DueToFireOrPhysicalDamage> <L3TreatStructureAsASingleZone>false</L3TreatStructureAsASingleZone> <HeritageCost>0</HeritageCost> <Lf3>0</Lf3> <L4DueToSpecialHazard>0</L4DueToSpecialHazard> <L4DueToStepAndTouchVoltage>0</L4DueToStepAndTouchVoltage> <L4DueToFireOrPhysicalDamage>0</L4DueToFireOrPhysicalDamage> <L4DueToOvervoltage>0</L4DueToOvervoltage> <costCa>0</costCa> <costCb>0</costCb> <costCc>0</costCc> <costCs>0</costCs> <hZ4>1</hZ4> <Lt4>0</Lt4> <Lf4>0</Lf4> <Lo4>0</Lo4> <Protection> <InsulationOfExposedConductor>false</InsulationOfExposedConductor> <EffectiveSoilEquipotentialization>false</EffectiveSoilEquipotentialization> <WarningNotices>false</WarningNotices> <PhysicalRestrictions>false</PhysicalRestrictions> <InsulationOfExposedConductorPTU>false</InsulationOfExposedConductorPTU> <WarningNoticesPTU>false</WarningNoticesPTU> <PhysicalRestrictionsPTU>false</PhysicalRestrictionsPTU> </Protection> <CostOfShockProtection>0</CostOfShockProtection> <LOSS0> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS0> <LOSS1> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS1> <LOSS2> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS2> <LOSS3> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS3> <LOSS4> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS4> <LOSS5> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS5> <LOSS6> <Np>0</Np> <Nt>0</Nt> <Tp>0</Tp> </LOSS6> </SRZone3> </Zones> <LightningProtectionSystem>1</LightningProtectionSystem> <PB>0.2</PB> <CostOfLPS>0</CostOfLPS> <Financial> <InterestRate>0.001</InterestRate> <AmortizationRate>0.001</AmortizationRate> <MaintenanceRate>0.001</MaintenanceRate> <CostOfLoss>0</CostOfLoss> </Financial> <UnprotectedCaseIndex>-1</UnprotectedCaseIndex> </SRCase3> </Cases> <Name>EN 62305:2010 Annex E Examples</Name> <Client>A. N. Other Contracting</Client> <Address>1234 A. N. Other Street A. N. Other Town A. N. Other county ANOT HER</Address> <Ref>Annex NE Examples</Ref> <CalculationRef>NA</CalculationRef> <CalculationNotes>The following calculation is taken from Annex E of NF EN 62305-2:2010 The example was based upon the equivalent example contained within IEC 62305-2:2010</CalculationNotes> <Author>A. N. Other</Author> </SRProject>